S/85
The Model S85 is an active device which is designed to give an alarm signal if fluid falls below a preset level. It will only signal an alarm after a few seconds of low level to eliminate false alarms due to turbulence.
The fact that the Model S85 has no moving parts and incorporates a built in delay means it is ideal in appliations where mechanically operated switches mis-trigger due to vibration and fluid turbulence.
The fact that the Model S85 has no moving parts and incorporates a built in delay means it is ideal in appliations where mechanically operated switches mis-trigger due to vibration and fluid turbulence.
Specifications
Fluid Types:
Water based fluids compatible with Brass, PTFE and NBR rubber.
Fluid Types:
Water based fluids compatible with Brass, PTFE and NBR rubber.
Connections:
See diagram below.
Note:
Test performed in accordance with BSEN 60068-2-64 : 1993
Electical Rating:
See diagram below.
Note:
- Outputs are factory selectable and dual outputs on output 1 are available on request.
- Vibration (15.3 grms)
- 3 orthoganol planes for 3 hours per plane
Frequency (Hz) 24 60 100 240 2000 |
G2/Hz 0.04 0.5 0.5 0.1 0.1 |
Test performed in accordance with BSEN 60068-2-64 : 1993
Electical Rating:
Supply Voltage: Supply Current: Max. Load Current: Alarm Delay Time: Connection: Start up Delay: |
5 VDC or 7 – 35 VDC 1.5mA + source output 1.0A (sink) or 20mA (source) 0 – 25 secs rising or falling (factory set) 4 way Delphi Packard connector 1 – 5 secs |
Construction:
Environmental Ratings:
Note: Torque setting on installation should not exceed 22Nm. Unit should be tightened with a 31mm ring spanner or 31mm socket.
Optional accessory:
Mating connector kit to suit harness wire cross sectional area of 0.8 to 1.0mm² and sleeve Ø1.60 to 2.15mm.
Body: Probe: Terminals: Seals: Connector: Thread sealant: |
Brass PTFE SAE CA210Brass, Tin Plated NBR rubber 30% Glass Filled Nylon 6 Polyacrylate Aqueous Emulsion Base (Dri-Seal 5061) – 1/4″ NPT only |
Environmental Ratings:
Sealing: Max. pressure: Temp. ranges: Weight: |
IP67 5.0 Bar (72 psi) Fluid: -40°C to +130°C Storage: -50°C to +140°C |
Note: Torque setting on installation should not exceed 22Nm. Unit should be tightened with a 31mm ring spanner or 31mm socket.
Optional accessory:
Mating connector kit to suit harness wire cross sectional area of 0.8 to 1.0mm² and sleeve Ø1.60 to 2.15mm.
Description:
Connector kit comprising of:
Connector kit comprising of:
- Crimp Terminals (x4)
- Cable seals (x4)
- Cavity plug (x1)
- Connector assembly 4 way (x1)
- TPA lock (x1)
- From the Packard Metri-Pack 150 series of connectors.